MAXIMUM POWER RATINGS WITHOUT DAMAGE
M2 / T3 / IQ / IR: +26 dBm at +25°C, derated linearly to +23 dBm at +100°C.
M1 / M3 / M4 / M8 / M9: +23 dBm at +25°C, derated linearly to +20 dBm at +100°C.
Doublers: +23 dBm at +25°C, derated linearly to +20 dBm at +100°C.
For devices with Local Oscillator or Doubler Input levels that exceed the above limits, the maximum rated power at +100°C is the maximum specified drive level.